The importance of supervised monitoring modules used in management and monitoring of extinguishing techniques

In many locations from chemistry laboratories to industrial facilities, in order to guarantee the security of life and property towards a attainable hearth hazard, extinguishing techniques are used along with detection and alarm techniques. It is also extraordinarily essential that the extinguishing systems installed can be triggered by the fire extinguishing management panel, so as to eliminate a possible hearth with early intervention.
In order to satisfy these wants, and with 35 years of sectoral data and experience, Mavili Elektronik offers:
Maxlogic Conventional Fire Extinguishing Control Panel operating according to the cross-zone detection principle;
Maxlogic Extinguishing Status Indicator Unit, which allows the remote efficiency of the indications and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which permits the extinguishing course of to be began manually and remotely; and
to guarantee that the extinguishing process may be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
All these gadgets are produced using surface-mount know-how and are aimed toward making the automation of the extinguishing system and fire and gas detection system good.
Image copyright: Mavili
Mavili Elektronik develops its products by at all times considering the needs of the installation. In circumstances that require the integration of the extinguishing system with the clever addressable fire detection system, it offers options by way of the monitoring modules that also have a ‘supervised’ possibility.
Supervised monitoring modules play an important role in controlling the continuity of the cable connection between the loop and the extinguishing system. Failure to detect a potential open or brief circuit in the wiring between the contact monitoring modules and the peripheral methods may cause disruption of the triggering, with probably important consequences. For this reason, when selecting monitoring modules, it must be taken into consideration that they’ve supervised options.
ที่วัดแรงดันน้ำ : Mavili
Since Maxlogic clever addressable fireplace detection and alarm management panels are constantly communicating with ‘supervise’ contact monitoring modules linked to cable loops and compliant with EN 54-17 and EN 54-18 requirements, it makes it simpler to watch conditions corresponding to open circuits and quick circuits that may happen within the system. Many duties could be performed in the fire extinguishing installation, such because the control and monitoring of all valves that can interrupt the flow of water, water move alarm switches, strain switch, and electric or diesel fireplace pumps.
By including two contact monitoring modules to 2 separate relay outputs positioned above the Maxlogic Conventional Fire Extinguishing Control Panel, one of the modules can be utilized to manage errors and the opposite to regulate the fireplace situation, monitoring and management of the extinguishing system by way of an clever addressable hearth detection and alarm system could be carried out effectively.
For more information, go to www.mavili.com.tr/en
Share

Scroll to Top